9861 Highway 165 N Sterlington, LA 71280 | Phone: 404-862-6422

If it rides or rolls and works for a living.. Then we handle it!

Water Truck

DCOMPLIANCE DATES—INSPECTIONS AND TEST UNDER §180.407(C)


Test or inspection (cargo tank specification, configuration, and service)

Date by which first test must be completed (see note 1)

Interval period after first test

External Visual Inspection:

 

 

All cargo tanks designed to be loaded by vacuum with full opening rear heads

September 1, 1991

6 months

All other cargo tanks

September 1, 1991

1 Year

Internal Visual Inspection:

 

 

All insulated cargo tanks, except MC 330, MC 331, MC 338 (see Note 4).

September 1, 1991

1 Year

All cargo tanks transporting lading corrosive to the tank

September 1, 1991

1 Year

All other cargo tanks, except MC 338

September 1, 1995

5 Year

Lining Inspection:

 

 

All lined cargo tanks transporting lading corrosive to the tank

September 1, 1991

1 Year

Leakage Test:

 

 

MC 330 and MC 331 cargo tanks in chlorine service

September 1, 1991

2 Years

All other cargo tanks except MC 338

September 1, 1991

1 Year

Pressure Test:

 

 

(Hydrostatic or pneumatic) (See Notes 2 and 3)

 

 

All cargo tanks which are insulated with no manhole or insulated and lined, except MC 338.

September 1, 1991

1 Year

All cargo tanks designed to be loaded by vacuum with full opening rear heads.

September 1, 1992

2 Years

MC 330 and MC 331 cargo tanks in chlorine service

September 1, 1992

2 Years

All other cargo tanks

September 1, 1995

5 Years

Thickness Test:

 

 

All unlined cargo tanks transporting material corrosive to the tank, except MC 338.

September 1, 1992

2 Years

 

NOTE 1: If a cargo tank is subject to an applicable inspection or test requirement under the regulations in effect on December 30, 1990, and the due date (as specified by a requirement in effect on December 30, 1990) for completing the required inspection or test occurs before the compliance date listed in table I, the earlier date applies.

 NOTE 2: Pressure testing is not required for MC 330 and MC 331 cargo tanks in dedicated sodium metal service.

NOTE 3: Pressure testing is not required for uninsulated lined cargo tanks, with a design pressure or MAWP 15 psig or less, which receive an external visual inspection and lining inspection at least once each year.

NOTE 4: Insulated cargo tanks equipped with manholes or inspection openings may perform either an internal visual inspection in conjunction with the external visual inspection or a hydrostatic or pneumatic pressure-test of the cargo tank.